2. jump start/battery charge controls, 3. determining battery charging current – Hobart Welding Products POWERPAK OM-478 User Manual

Page 33

Advertising
background image

OM-478 Page 29

7-2.

Jump Start/Battery Charge Controls

Ref. ST-184 780-C

1

Output Selector Switch

Y

Do not switch under load.

Use switch to select weld or battery
charge/jump start output. Output
automatically stops when terminal
voltage is 15 to 25 percent above
required battery voltage. Move
switch to weld position when done
charging/jump starting.

2

Battery Voltage Selector
Switch

Place switch in position matching
voltage of battery being jump
started or charged.

3

Battery Charge/Jump Start
Selector Switch

Use switch to select battery jump
start or charging output.

4

Battery Light

If light comes on while charging or
jump starting, stop the engine and
check the following:

a.

Polarity of connections (+
and –)

b.

Battery Voltage switch
position

c.

Output Selector switch
position

d.

Battery voltage.

1

2

3

4

7-3.

Determining Battery Charging Current

1

Battery Charging Chart Chart

Find battery cold crank amp (CCA)
rating on battery. Use CCA rating
on chart to find charge current set-
ting for battery.

EXAMPLE: If battery CCA rating is
500, charging current from chart is
100 amperes.

Do not exceed charging current
found on chart. For longer battery
life, use lowest charge rate
possible.