OM-478 Page 31

7-5.

Jump Starting Procedure

Ref. ST-184 780-C

.

Charge battery for 10 minutes
before jump starting battery
(see Section 7-4).

Set Output (Contactor)

Switch to Remote. Turn

Off Remote Device.

Set A/V control to max (100) and Ampere

Range switch to CV position.

Charge Battery For 10

MInutes (See Section 7-4).

Press Remote Momentary On Switch

While Cranking Engine Of Equipment Be-

ing Jump Started. Release Switch When

Equipment Starts. Stop Welding Generator

And Disconnect Cables.

Press switch only
while cranking en-
gine of equipment
being started.

Set Charge/Jump Start

Switch To Jump Start.

Y

Do not switch Ampere Ranges
while under load.

SECTION 8 – MAINTENANCE & TROUBLESHOOTING

The air compressor normally requires service every 1200 hours of operation if
used regularly and operated in a clean, dry environment. The compressor will
require service more often if used infrequently or operated in dirty, humid
conditions.

To help minimize air compressor maintenance, use sufficient quantities of air to
allow compressor to cycle for a minimum of one hour per week.

Follow the storage procedure in the engine owner’s manual if the unit will not be
used for an extended period.