Hand Held Products 5700 User Manual

Page 81

Advertising
background image

7–5

SCANTEAM 5700 User’s Guide

RS–232

5700–X1, 5700–X2 (TTL) and 5700–X3 (True)

Decoded output data format is provided at the modular connector in the scanner
handle.

Signal

Function

Interface cables normally supplied with scanner model 5700–X1, 5700–X2
(TTL), and 5700–X3 (True) are terminated with an 10 pin modular plug (P1) and
a 9 pin Type D connector (P2) that is compatible with all Welch Allyn terminals.
See chart below.

9

7
8

4

3

5
6

2

SH

6
5

2

8
7

3

P2

9 Pin Type D Female

6

9

1

5

+5VDC

RTS

Ground

DTR

RXD

TXD

Braid

Clear to Send Data

5 Volt Power Connection

Request to Send Data

Supply Ground

Data Terminal Ready

Receive Data – Serial Data to Scanner

Transmit Data – Serial Data from Scanner

Cord Shield

CTS

P1

P2

View A–A

P2 connects to

your terminal.

470

470

SH

1

2

P3

P3

4 Pin Type Mini–DIN

1

2

3

4

View B–B

P3 connects to

the external

power supply.

P1

10 Pin Modular Plug

Pin 1

Pin 10

P1 connects to the
scanner handle.

Advertising