C. clearances – Heatiator CB4842IR User Manual

Page 18

Advertising
background image

Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09

8

0 in.

C

B

A

Note: All pipe clearance

specifications are per vent

manufacturer's installation

instructions.

0 (Clearance to

Standoffs)

30 in.

(762 mm)

clearance to ceiling

1/2 in. (13 mm)

1/2 in.

(13 mm)

Drywall

0 in.

Per Vent

Manufacturer’s

Specifications

Combustible flooring may be installed

next to the front of the appliance.

Combustible Object

36 in.

(914 mm)

A

Rough Opening

(Width)

B

Rough Opening

(Height)

C

Rough Opening

(Depth)

in.

42

38-3/4

23-1/2

mm

1,067

984

597

in.

48

38-3/4

23-1/2

mm

1,219

984

597

CB4236I

CB4842I

Model

Figure 5.2 Clearances to Combustibles

C. Clearances

WARNING! Risk of Fire! Maintain specified air space

clearances to appliance and vent pipe:
• Insulation and other materials must be secured to

prevent accidental contact.

• The chase must be properly blocked to prevent blown

insulation or other combustibles from entering and

making contact with fireplace or chimney.

• Failure to maintain airspace may cause overheating and

a fire.

Note: If the inside of the framed cavity is to be finished,

the framing dimensions must include the finished surface.

Example: If drywall is to be attached to the rear wall, the

depth must be measured from the drywall surface.

Note: The appliance must be raised 1 1/4 in. (32 mm) off floor so

the Harbor System can be used. Adjust framing and vent locations

accordingly.

NOTICE: Install appliance on hard metal or wood surfaces

extending full width and depth.

DO NOT install directly on

carpeting, vinyl, tile or any combustible material other than

wood.