Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09

26

B. Intellifire Ignition System Wiring

• Wire the appliance junction box to 0 VAC for proper

operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT

wire IPI controlled appliance junction box to a switched

circuit. Incorrect wiring will override IPI safety lockout.

• Refer to Figure 12.1. Intellifire Pilot Ignition (IPI) Wiring

Diagram.

C. Optional Accessories Requirements

• This appliance may be used with a wall switch, wall

mounted thermostat and/or a remote control.

• Wiring for optional Hearth & Home Technologies

approved accessories should be done now to avoid

reconstruction. Follow instructions that come with those

accessories.

A. Wiring Requirements

NOTICE: This appliance must be electrically wired

and grounded in accordance with local codes or, in the

absence of local codes, with

National Electric Code

ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.
• Wire the appliance junction box to 0-20 VAC. This is

required for use of optional accessories (standing pilot

ignition) or proper operation of the appliance (Intellifire

ignition).

• A 0-20 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in

compliance with the applicable electrical codes, when

it is installed in locations such as in bathrooms or near

sinks.

• Low voltage and 0 VAC voltage cannot be shared

within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire

110V to the valve or to the appliance wall switch. Incorrect

wiring will damage controls.

12

Electrical Information

Ignitor

Flame

Sensor

Pilot Assembly

GRN

ORG

BLK

ORG

Control

Box

To

Junction

Box

Battery

Pack

3V

Adaptor

BLK

BRN

RED

RED

BLK

BLU

Valve

Limit

Switch

WHT

+

- +

-

Optional SPST

Wall Switch

OR

Optional Remote

WHT

GRN*

* GRN wire only used with

optional wall switch

WSK-MLT-HTL

D. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to

disconnection when servicing controls. Wiring errors can

cause improper and dangerous operation. Verify proper

operation after servicing.

Figure 12.1 Intellifire Pilot Ignition (IPI) Wiring Diagram

WARNING! Risk of Shock! Replace damaged wire with

type 105° C rated wire. Wire must have high temperature

insulation.

• This appliance is equipped with an Intellifire control valve

which operates on a  volt system.

• Plug the -volt AC transformer into the appliance junction

box to supply power to the unit OR install two D cell

batteries (not included) into the battery pack before

use.

NOTICE: Batteries should not be placed in the battery

pack while using the transformer. Remove batteries before

using the transformer, and unplug the transformer before

installing the batteries. Battery polarity must be correct or

module damage will occur.