Heatiator CB4842IR User Manual

Page 31

Advertising
background image

Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09



M. Air Shutter Setting

Air shutter settings should be adjusted by a qualified

installer at the time of installation. The air shutter is set at

the factory for minimum vertical vent run. Adjust air shut-

ter for longer vertical runs.
• It takes 6 full turns of the shutter adjustment handle to

move the air shutter from fully open to fully closed.

• When the air shutter adjustment handle is all the way

down, the air shutter is in the closed position.

NOTICE: If sooting occurs, provide more air by opening

the air shutter.

K. Install Louvers and Trim

• Install optional trim kits and/or surrounds using the

instructions included with the accessory.

• Use non-combustible materials to cover the gap between

the sheet rock and the appliance (if desired).

• Do not obstruct or modify the air inlet/outlet grilles.

• Leave space to lower the bottom grille and remove the

trim door.

L. Hood

• Align back edge of hood with attachment clips and press

firmly in place.

Closed

Figure 14.9 Air Shutter