24 suppressing second-trace echoes, 23.3 setting watchman stand-by interval – Furuno 1834C-BB User Manual

Page 51

Advertising
background image

2. RADAR OPERATION

2-24

Note:

When the watchman is activated and no guard zone is active, the message “PLEASE

SET GUARD ZONE. PUSH ANY KEY TO CONTINUE.” appears. Press any key and then
set a guard zone.

2

.23.3 Setting watchman stand-by interval

The watchman standby interval, that is, the number of minutes the radar is in standby, can
be set to 5, 10 or 20 minutes as follows:

1. Press the MENU key.
2. Press the A: RADAR DISPLAY SETUP soft key.
3. Select WATCHMAN TIME, then press the A: EDIT soft key.

WATCHMAN

 TIME

  5 minutes
10

 minutes

20

 minutes

Watchman window

4. Select time desired, then press the C: ENTER soft key.
5. Press the MENU key to close the menu.

2.24 Suppressing Second-trace Echoes

In certain situations, echoes from very distance targets may appear as false echoes
(second-trace echoes) on the screen. This occurs when the return echo is received one
transmission cycle later, or after a next radar pulse has been transmitted.

Second-trace
echo

Tx repetition

Actual range

False echo
range

Second-trace echoes

To activate or deactivate the second-trace echo rejector do the following:

1. Press the MENU key.
2. Press the A: RADAR DISPLAY SETUP soft key.
3. Use the Trackball to select 2ND ECHO REJECTION, then press the A: EDIT soft key.
4. Choose ON or OFF as appropriate, then press the C: ENTER soft key.
5. Press the MENU key to close the menu.

Advertising
This manual is related to the following products: