2 acquiring and tracking targets (arp) – Furuno 1834C-BB User Manual

Page 54

Advertising
background image

2. RADAR OPERATION

2-27

2.26.1 Activating/deactivating ARP, TTM

1. Press the MENU key followed by the C: ARP SETUP soft key to show the ARP SETUP

menu.

ARP
SETUP

ARP TARGET INFO

INTERNAL ARP

CANCEL ALL TARGETS

NO

ARP VECTOR MODE

TRUE

ARP VECTOR TIME

30 minutes

HISTORY INTERVAL

OFF

CPA

OFF

TCPA

30 seconds

AUTO ACQUISITION AREA OFF

TARGET ID NUMBER

OFF

RETURN

E

EDIT

A

ARP setup menu

2. Select ARP TARGET INFO, then press the A: EDIT soft key to show the ARP target info

window.

ARP TARGET INFO

INTERNAL ARP
EXTERNAL ARP
OFF

ARP target info window

3. Select INTERNAL ARP, EXTERNAL ARP or OFF as appropriate.

INTERNAL ARP:

The radar source must be an ARP-equipped Model 18x4-BB/19x4-BB

series NavNet radar. Select this item also for a NavNet unit being fed ARP targets.

EXTERNAL ARP:

Receive TTM data sentence via NMEA or NETWORK port. Target

tracks are shown but targets cannot be acquired.

OFF:

Turns off the ARP or TTM display.

4. Press the C: ENTER soft key.
5. Press the MENU key to close the menu.

2.26.2 Acquiring and tracking targets (ARP)

Ten targets may be acquired and tracked manually and automatically. When you attempt to
acquire an 11th target, the message “ARP FULL – ALREADY TRACKING 10 TARGETS!”
appears for five seconds. To acquire another target, terminate tracking of an unnecessary
target as shown in the paragraph “2.26.4 Terminating tracking of ARP targets.”

Manual acquisition
When the automatic acquisition (AUTO ACQ. AREA) is set to on, up to five targets may be
acquired manually. If you attempt to acquire a sixth target, the alert message appears.