2. RADAR OPERATION

2-29

CANCEL ALL TARGETS

YES
NO

Cancel all targets window

2.26.3 Displaying target number (ARP, TTM)

Target number can be shown for ARP and TTM targets as below.

TARGET

359.9 ˚R

11.70

nm

+

ARP
Target
Number

01

12/

H-UP

3nm
LP

319. 9

°

T

RETURN

E

TARGET
INFO

D

TRAIL

A

TLL
OUTPUT

B

ACQ

C

ARP target number

1. Press the MENU key.
2. Press the C: ARP SETUP soft key.
3. Select TARGET ID NUMBER.
4. Press the A: EDIT soft key.
5. Select ON or OFF as appropriate.
6. Press the C: ENTER soft key.
7. Press the MENU key to close the menu.

2.26.4 Terminating tracking of ARP targets

When ten targets have been acquired, no more acquisition occurs unless targets are
cancelled. If you need to acquire additional targets, you must first cancel one or more
individual targets, or all targets, using one of the procedures below.

Terminating tracking of selected targets

1. Place the cursor on the target to terminate tracking.
2. Press the CLEAR key to terminate tracking and erase the target.

Terminating tracking of all targets

1. Press the MENU key followed by the C: ARP SETUP

soft key.

2. Select CANCEL ALL TARGETS.
3. Press the A: EDIT soft key.
4. Select YES.
5. Press the C: ENTER soft key.
6. Press the E: RETURN soft key followed by the MENU

key to close the menu.