9 lost target alarm (arp) – Furuno 1834C-BB User Manual

Page 60

Advertising
background image

2. RADAR OPERATION

2-33

Follow the steps shown below to set the CPA/TCPA alarm
range:

1. Press the MENU key followed by the C: ARP SETUP soft

key.

2. Operate the Trackball to select CPA.
3. Press the A: EDIT soft key to show the CPA window.
4. Select a CPA limit desired from 0.5 nm, 1 nm, 2 nm, 3

nm, 5 nm and 6 nm with the Trackball.

5. Press the C: ENTER soft key. The ARP SETUP menu

reappears.

6. Operate the Trackball to select TCPA.
7. Press the A: EDIT soft key to show the TCPA window.
8. Select a TCPA limit from 30 sec, 1 min, 2 min, 3 min, 4

min, 5 min, 6 min and 12 min.

9. Press the C: ENTER soft key.
10. Press the MENU key to close the menu.

2.26.9 Lost target alarm (ARP)

When the system detects a lost target, the target symbol
becomes a diamond and tracking is discontinued after one
minute.

01

Lost target mark

Canceling a lost target

1. Place the cursor on the target.
2. Press the CLEAR key.

CPA

{

{

{

{

{

{

~

OFF
0.5nm
1nm
2nm
3nm
5nm
6nm

CPA distance

TCPA

{

{

{

{

{

{

{

~

30 seconds
1 minute
2 minutes
3 minutes
4 minutes
5 minutes
6 minutes
12 minutes

TCPA time

Advertising