C-9

Rate of operation

The TX rate or operation is the percentage of data output in one second, and it
appears on the screen. If short intervals are assigned to many sentences, the
rate of operation increases as illustrated below.

TX

TX

TX

A rate of operation exceeding 100% is impractical. For better performance, the
rate of operation should be less than 90%.

DATA1 output setting

1. Press [MENU], [9] and [3] keys to show the DATA1, 3 OUTPUT SETUP

menu.

Talker ID GP LC DE

Output Data (00-90 sec)81%

1. AAM:00 APA:00

APB:04 BOD:00

2. BWR:00 BWW:00 GGA:00 GLL:01

3. RMB:01 RMC:01 VTG:01

WCV:01

4. WNR:00 WPL:00 XTE:00

ZDA:01

5. GNS:00 ZTG:01

Rnn:00

RTE:00

DATA3. Log Pulse 200ppm 400ppm

DATA 1, 3 OUTPUT SETUP

MENU : Escape

ENT : Enter

Settings shown here are default settings.

This line appears only when LOG is
selected by internal jumper wires.

Data Fmt.

V1.5

V2.0

IEC

200ppm

Figure 4-1 DATA1, 3 OUTPUT SETUP menu

2. Press ▲ or ▼ to select DATA FMT
3. Press ◄ or ► to select V1.5, V2.0 or IEC.
4. Press the [ENT] key. Talker ID appears in reverse video.
5. Press ◄ or ► to select GP, LC or DE.
6. Press the [ENT] key.
7. Enter TX interval for each output data sentence in line 1. TX interval is

available in 00, 01, 02, 03, 04, 05, 06, 10. 15, 20. 30, 60 and 90 msec.

8. Press the [ENT] key.
9. Enter TX interval for each output data sentence in lines 2 through 5. Press

the [ENT] key after setting each line.