B – 4

Output signal (contact closure signal)

J10 (WPT alarm)

J11

J12

Pin no.

Designation

Pin no.

Designation

Pin no.

Designation

#1

Alarm signal

#1

Alarm signal

#1

Alarm signal

#2

Alarm signal

#2

Alarm signal

#2

Alarm signal

#3

GND

#3

GND

#3

GND

Selection of output data format

The output data format is selectable by changing a jumper block; A for RS-422 and B for
NMEA. For example, to select NMEA for J4, change the jumper block from A to B on J401
and J402. Do the same on J5 thru J9.

J10 (WPT alarm)

J11

J12

Output

Jumper

Output

Jumper

Output. Jumper

J4

J401/J402 (A)

J5

J501/J502 (A)

J6

J601/J602 (A)

J7

J701/J702 (A)

J8

J801/J802 (A)

J9

J901/J902 (B)

Default of jumper setting is shown in parenthesis.

Maintenance

Fuse replacement

If the fuse blows, find the cause of the problem before replacing it. Do not use a fuse rated
more than 0.5A, since it may cause more serious damage to the equipment.

Self test 1

The unit performs an internal self-check in the following sequence each time power is turned
on.

1) LEDs CR7 to CR10 blink twice every 2 seconds.

2) ROM and RAM are tested.

3) LED CR13 blinks every second for normal operation. If an error is detected during the

test, the corresponding LED is turned on.

• When CR7 is on, ROM is defective.
• When CR8 is on, RAM is defective.