Connections – Furuno DD-80 User Manual

Page 89

Advertising
background image

B – 3

Grounding

To prevent electrical shock and mutual interference, run a ground wire between the earth
terminal on the unit and ship’s superstructure.

Cabling schedules

The signal cable should be a twisted-pair, double-screened cable. Ground the signal cable at
the cable clamp.

Connections

Power supply

J1 (10 to 35 VDC)

Pin no.

Designation

#1

+

#2

Input signal (NMEA)

The signal from DGPS is connected to J2 and J3. Data being fed to J2 has higher priority
than J3.

J2

J3

Pin no.

Designation

Pin no.

Designation

#3

NMEA RD1-H

#3

NMEA RD2-H

#4

NMEA RD1-C

#4

NMEA RD2-C

#6

GND

#6

GND

Output signal (RS-422 or NMEA)

J4, J5, J6, J7, J8, J9

Pin no.

Designation

#1

TD-H

#2

TD-C

#4

GND