4troubleshooting, 4 troubleshooting – Furuno DD-80 User Manual

Page 69

Advertising
background image

9 – 3

9.4 Troubleshooting

The table which follows provides troubleshooting procedures which you can follow to restore
normal operation. If normal operation cannot be restored, ask your dealer for advice.

Table 9-1 Troubleshooting table

If...

Then...

you cannot turn on the
power

• check power connector for tight connection.

• check if ship's mains is off.

• check for blown fuse.

position cannot be fixed

• check antenna cable for tight connection and water leakage.

• check if functional satellite has been disabled: [MENU ESC] [9] [6]

position is wrong

• check if correct geodetic chart is entered: [MENU ESC] [9] [6]

• apply position correction to GPS position: [MENU ESC] [9] [6]

position sometimes cannot
be fixed

• DOP figure may be too small. Enter larger figure; 20 is the usual
setting.

data cannot be transmitted
to external equipment

• check if data format is correct: [MENU ESC] [9] [3] ([9] [4] or [9] [5])
See the installation manual for further details.

• Tx interval may be set to "0". Select proper interval:
[MENU ESC] [9] [3] ([9] [4] or [9] [5])
See the installation manual for further details.

• Check appropriate settings on external equipment.

• Check connections:

DD-80 Ext. equipment

TXD-H RXD-H
TXD-C RXD-C

Advertising