Alarm setting procedure – Furuno CI-35H User Manual

Page 54

Advertising
background image

4-12

ALARM setting procedure

1. Call “ALARM SET” menu by pressing the

ALARM

key.

2. By the

knob, place the vertical cursor an the desired item; then select an option item by the

knob.

3. Press the

EVENT

key. The subsequent action depends on the location of the horizontal cursor.

1) When the horizontal cursor is on a speaker mark, the

EVENT

key functions to turn the

audible alarm OFF “

” or ON “

”.

Note that the audible alarm sounds for the items
with a filled star mark “

” beside them.

2) When the horizontal cursor is on an item which has the hollow star “

” aside it or no star

mark, the range set display appears.

Ex.

Selected “LAYER1” - “SPD

Present tide
vector for layer 1.

MAX

MIN

Alarm range (zone)

MAX

MIN

SET

1. 2kt

280

°

LYR1 SPD

MIN 0.5kt

MAX 1.0kt

LYR1 DIR

MIN 0

MAX 0

As necessary, change alarm range (zone) by

knob (MAX) and

knob (MIN), and then press

the

EVENT

key. The hollow star “

” changes to the filled star “

” to indicate the alarm setting

is valid (or active).

EVENT

Audible Alarm
“ON”

Audible Alarm
“OFF”

Advertising