Furuno CI-35H User Manual

Page 55

Advertising
background image

4-13

3) When the horizontal cursor is on an item which has the filled star mark “

”, beside it, the

following sub-menu appears.

ALARM/ALARM ZONE SETTING KNOB SETUP

SELECT : SET ZONE STOP ALM

PRESS EVENT KEY TO ENTER

To make alarm setting valid;

1 Place the horizontal cursor on “SET ZONE” by

knob, and press the

EVENT

key. The

alarm zone setting display appears.

EX.

Selected “1ST LAYER” - “DIR

MAX

MIN

MAX

MIN

SET

1. 2kt

280

°

LYR1 SPD

MIN 0.5kt

MAX 1.0kt

LYR1 DIR

MIN 45

°

MAX 90

°

2 As necessary, change alarm zone by

(MAX) and

(MIN), and then press the

ENTER

key.

To make alarm setting invalid;

1 In the alert message window, select “STOP ALM” by

knob, and press the

EVENT

key. The filled star “

” aside the option item changes to the hollow star “

” to show the

alarm setting is now invalid. (Alarm zone settings are preserved, but they do not trip the
alarm.)

4. After entering the alarm/alarm zone, press the

ALARM

key to store the settings and to close the

alarm menu window.

5. When the conditions of an alarm are breached, with ship’s movement or tide movement, the

alarm message starts blinking at the bottom part of the display. If the audible alarm is enabled
for that item, the alarm sounds.

¡ To cease the audible alarm, call the alarm menu and disable (OFF) the audible alarm

(

), or make the alarm setting invalid (“

”.)

¡ To mute the audible alarm temporarily, turn the VOLUME control counter-clockwise.

Advertising