Single (single cycle), Conti (continuous: repeat) – Furuno CI-35H User Manual

Page 60

Advertising
background image

5-2

3. Place the item cursor on “SELF CHECK” by the

knob, and then press the

EVENT

key. As

this item is protected (locked), the following alert appears.

MENU SELECT IS LOCKED SET TO UNLOCK

UNLOCKED NO YES

PRESS EVENT KEY TO ENTER

4. Select ‘YES’ by the

knob and press the

EVENT

key. The color of “SELF CHECK” turns

green to show the item is unlocked.

5. Select a check option, SINGLE, CONTI, PANEL or ECHO by the

key, and then press the

EVENT

key to start the self check.

SINGLE (single cycle)

The SINGLE test executes the system check for one cycle displaying the test result for each item
checked. Items checked are ROM/RAM and P.C. boards for the Display unit and the Transceiver
unit. Echo strengths from three transducers are also displayed in the ECHO LEVEL frame.

ERROR

No. 002

104

SYSTEM CHECK

CI-3500

CI-3510

If abnormal, some error
number should remain.

See the table on
page 4-5 to identify
the cause of error.

CONTI (continuous: repeat)

The CONTI test executes the system check repeatedly. To escape, press the

MENU

key.

Advertising
This manual is related to the following products: