Range set menu – Furuno CI-35H User Manual

Page 52

Advertising
background image

4-10

2. RANGE SET MENU

RANGE

2.0kt

5.0

NM

100m

2

Distance range

For course plot
display

4

Color gradation range

For echo level display
in color mode

1

Speed range

For speed vector
graph

3

Depth range

For echo level
display

1. To change one of the above ranges, call the RANGE SET menu by pressing the

RANGE

key.

*RANGE SET*

KNOB ITEM

KNOB SETUP

END : RANGE

SPEED RANGE

: 10.0 kt

DIST RANGE

: 1.0 NM

ECHO DEPTH

: 150 m

ECHO SHIFT

: 1

Knob

Knob

(Note 1)

1

Max. speed range
of tide/tide
differential vector
display

2

Distance from center

(ship’s position) to
outermost ring (for
course plot display)

1.0 to 20.0 kt in
0.1 kt steps

0.5 to 5.0 nm in
0.5 nm steps

3

Max. depth range for

“echo level” display

50 to 700 meters in
50 meter steps

4

Color gradation factor
for “echo level” display
( * )

(1 to 36)

(Note 1) Changes the threshold levels for coloring echoes

with different strengths. (The higher the value, the
lower the thresholds, and vice versa.)

A gradation factor of 1 to 7 is recommended. The
higher (lower) the value, the greater the amount of
red (blue) in echoes.

Notice that the threshold shift dose not change the
receiver gain nor performance of the equipment,
although it changes echo color.

2. When desired range is set, press the

RANGE

key again.

Advertising