Chapter 5. troubleshooting, Self-check, Warning – Furuno CI-35H User Manual

Page 59

Advertising
background image

5-1

CHAPTER 5. TROUBLESHOOTING

1. SELF-CHECK

The CI-35/35H has a self-test facility for general diagnosis of its major circuits. If an unusual
symptom is encountered during operation of the equipment, perform the self-check. If the self
check reveals equipment fault, shown by the error code, report the results to the service technician
when calling for service. (The user should not attempt further check inside the equipment.)

Do not open the cover of
the equipment.

This equipment uses high
voltage electricity which can
shock, burn, or cause death.
Only qualified personnel
should work inside the
equipment.

WARNING

Procedure

1. Call menu window by the pressing the

MENU

key.

2. Select “MENU MODE” - “MENU 2” by the

and

knobs.

* MENU 2 *

KNOB ITEM

Jan/15/1997

KNOB SETUP

END : MENU KEY

MENU MODE

: MENU1

MENU2

MENU3

MENU4

REF DEPTH

: OFF

E/S

BEAM TEST

: OFF

SELF CHECK

: SINGLE

DEMO DATA

: OFF DP3. 4 LOG10

TRIP RESET

DATE/TIME

: RESET (0. 00)

: TIME DATE

MENU SELECT

: LOCK UNLOCK

MENU SET

: FACTORY

CONT1 PANEL ECHO

Advertising