G0588/G0591 12" Sliding Table Saws

In the event of an electrical short, grounding
reduces the risk of electric shock. The ground-
ing wire in the cord must be properly connected
to the grounding prong on the plug; likewise, the
outlet must be properly installed and grounded.
All electrical connections must be made in accor-
dance with local codes and ordinances.

Improper connections of the electrical-grounding
conductor increases the risk of electric shock.
Check with a qualified electrician or one of our
service personnel if you do not understand
the grounding instructions, or if you doubt the
machine is properly grounded.

Grounding

Electrocution or fire could

result if this machine is

not grounded correctly

or if your electrical con-

figuration does not com-

ply with local and state

codes. Ensure compliance

by checking with a quali-

fied electrician!

The Model G0588 can be rewired for 440V oper-
ation. This rewiring job consists of disconnecting
the saw from the power source, replacing the
magnetic switch, and rewiring the motor.

The necessary magnetic switch for this proce-
dure can be purchased by calling our Customer
Service number at (800) 523-4777.

This procedure takes moderate electrical skill
and the rewiring job must be inspected by a quali-
fied electrician before the saw is connected to the
power source.

To rewire the Model G0588 for 440V opera-
tion:

1. Disconnect the saw from the power

source!

2. Remove the control panel cover plate shown

in

Figure 6.

Rewiring to 440V

Figure 6. Control panel cover plate.

When using a phase converter, the power from
the manufactured power leg (sometimes called
the wild wire) can fluctuate. Connect the manufac-
tured power leg to the S terminal to prevent dam-
age to the electrical controls. The wire from the S
terminal can handle some fluctuation because it
goes directly to the motor. The power going to the
R and T terminals goes to the electrical controls
and must be consistent to prevent damage. See
the instruction manual included with the phase
converter for more information.

Phase Converter