g0682 12" Cold Cut saw (mfg. since 12/10)

Cutting fluid

filling Cutting fluid Reservoir

1. disCoNNeCt saW From poWer!

2. remove the cap screws and washers from

the cutting fluid reservoir (

figure 34).

Draining/Cleaning Cutting fluid

Reservoir

1. disCoNNeCt saW From poWer!

2. Wearing protective equipment, drain and dis-

pose the cutting fluid following government-
approved disposal regulations for your area.

3. use a rag to wipe out residual fluid and

sludge.

4. Clean the cutting fluid screens in the machine

base and the tank (

figure 35).

Used cutting fluid is a

poison hazard. Use per-

sonal protection when

handling this material.

failure to do so may

result in illness or death.

3. slide the tray out from the machine base.

4. Wearing protective equipment, fill the reser-

voir with 2¼ quarts of a suitable, water-based
cutting fluid. refer to the manufacturer's
specifications for the proper water/oil mix.

5. slide the tray back into the base and replace

the cap screws and washers.

figure 34. opening cutting fluid reservoir.

Cap screws

Cutting Fluid reservoir

figure 35. Cutting fluid screens.

Cutting Fluid screens

Tip: Place a magnet in the cutting fluid reservoir
under the drain screen to collect metal chips and
prevent them from being drawn into the pump.
Periodically remove and clean the magnet.