CODES

(HEX/CONTROL) : 07 / <BEL>

FUNCTION :

Deferred drive command for peripheral unit 1

DETAIL DESCRIPTION :

Execute drive pulse for peripheral unit 1

when this code is processed (deferred).

CODES

(HEX/CONTROL) : 09 / <HT>

FUNCTION :

Execute horizontal tab.

APPLICATION LIMIT :

When no horizontal tab position is set, this

code is ignored.

DETAIL DESCRIPTION :

The print position skips to the next

horizontal tab position in same line. However, underline and overline do not
take place in the spaces between characters set with the horizontal tab function.

CODES

(HEX/CONTROL) : 0A / <LF>

FUNCTION :

Line feed

DETAIL DESCRIPTION :

Data in the line buffer is printed out and one

line is fed. If data does not exist before this code is received, the printer only
feeds one line.

CODES

(HEX/CONTROL) : 0B / <VT>

FUNCTION :

Execute vertical tab.

APPLICATION LIMIT :

When no vertical tab is set, line feed is not

performed.

DETAIL DESCRIPTION :

Prints data before this command as <LF>

does and feeds the paper to the next vertical tab set position. If the current line is
at or below the last vertical tab set position, the paper feeds to the top of the next
page.