CODES

(HEX/CONTROL) : 1B 7A 00 / <ESC> “z” <0>

FUNCTION :

Set 1/12 inch line feed

DETAIL DESCRIPTION :

Line feed is set at 1/12 inch after this code is

received, and is effective since first <LF> received after this command.

CODES

(HEX/CONTROL) : 1B 7A 01 / <ESC> “z” <1>

FUNCTION :

Set 1/6 inch line feed

DETAIL DESCRIPTION :

Line feed is set at 1/6 inch after this code is

received, and is effective since first <LF> received after this command.

CODES

(HEX/CONTROL) : 1B 7A 30 / <ESC> “z” “0”

FUNCTION :

Set 1/12 inch line feed

DETAIL DESCRIPTION :

Line feed is set at 1/12 inch after this code is

received, and is effective since first <LF> received after this command.

CODES

(HEX/CONTROL) : 1B 7A 31 / <ESC> “z” “1”

FUNCTION :

Set 1/6 inch line feed

DETAIL DESCRIPTION :

Line feed is set at 1/6 inch after this code is

received, and is effective since first <LF> received after this command.

CODES

(HEX/CONTROL) : 1C / <FS>

FUNCTION :

Immediate drive command for peripheral unit 1

DETAIL DESCRIPTION :

Execute drive pulse for peripheral unit 1

immediately. This code differs from the <BEL> code as follows: When the
printer receives an <FS> code, the command is executed immediately. The
<BEL> code is stored in the data buffer in the same manner as other codes, and
executed in the order in which they are received.