58D6056

17

CSDV Series Direct Vent Gas Stove

HOT

H

V

ST1139
Horizontal termination

VENTING INSTALLATION

Figure 21 -
Horizontal Termination Configuration for
Rigid Venting Using One (1) 90° Elbow

ST1139

Table 2 - Horizontal Venting

maximum

Vertical

Vertical

Vertical

Horizontal (H)

minimum

minimum

minimum

CSDV20 (V) CSDV30 (V) CSDV40 (V)

24"

41Z\x"

52Z\x"

54Z\x"

(610 mm)

(1054 mm)

(1334 mm)

(1384 mm)

20'

95Z\v"

98C\v"

102Z\v"

(6 m)

(2419 mm)

(2508 mm)

(2597 mm)

NOTE: Add 1/4" rise per 12" horizontal length of pipe.
NOTE: This configuration is for use with corner
installation also.

H

1

H

V

ST1140
Horiz term 2 elbows

Figure 22 -
Horizontal Termination Configuration for Rigid Venting Using
Two (2) 90° Elbows

Table 3 - Horizontal Venting with Two (2) 90° Elbows

maximum

Horizontal

Vertical minimum

H + H

1

CSDV20 (V) CSDV30 (V) CSDV40 (V)

24"

41Z\x"

52Z\x"

54Z\x"

(610 mm)

(1054 mm)

(1334 mm)

(1384 mm)

20'

95Z\v"

98C\v"

102Z\v"

(6 m)

(2419 mm)

(2508 mm)

(2597 mm)

NOTE: Add 1/4" rise per 12" horizontal length
of pipe.