Monessen Hearth CSDV40SLP User Manual

Page 8

Advertising
background image

8

58D6056

CSDV Series Direct Vent Gas Stove

W

ARNING

CLEARANCES

CLEARANCES TO COmBUSTIBLES

The dimensions shown in Figures 4 and 5 are minimum clearances to maintain
in installing this heater. Left and right clearances are determined when facing
the front of the heater.
Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material
other than wood flooring. If installed on carpet or vinyl flooring, the appliance
shall be installed on a metal, wood or noncombustible material panel extending
full width and depth of the appliance.

A

E

Minimum

D

Minimum

to Either

Side Wall

ST1128

sidewall clearance

Ceiling

Mantel

Side
Wall

Side
Wall

ST1128

Front View

B

C

F

Minimum

36” (914 mm)

in Front

St1129

mantel clearances

Ceiling

Side View

ST1129

G

G

ST1130
corner clearance

Corner
Installation

ST1130

Minimum

D

Minimum

to Either

Side Wall

ST1131

sidewall clearance

Wall Installation

ST1131

mantel Clearance from

Corner

Top of Unit

Side measured from Top

Rear

measured

min. Ceiling

max

measured

From Top

from Floor

protrusion

Height

Right

Left

From Back

Corners

product

A

B

C

D

E

F

G

CSDV20

72" (1829 mm) 12" (305 mm)

22" (559 mm) 4" (102 mm)

4" (102 mm)

1" (25 mm) 1/2" (13 mm)

CSDV30

72" (1829 mm) 12" (305 mm)

34" (864 mm) 4" (102 mm)

4" (102 mm)

1" (25 mm) 1/2" (13 mm)

CSDV40

72" (1829 mm) 12" (305 mm)

34" (864 mm) 4" (102 mm)

4" (102 mm)

1" (25 mm) 1/2" (13 mm)

Figure 4 -
Minimum Clearances
to Walls and Ceiling

Advertising