Monessen Hearth CSDV40SLP User Manual

Page 35

Advertising
background image

58D6056

35

CSDV Series Direct Vent Gas Stove

TROUBLESHOOTING

NOTE: All troubleshooting items are listed in order
of operation.

W

ARNING

Turn appliance OFF and allow to cool before
servicing. Only a qualified service person
should service and repair the heater.

OBSERVED pROBLEm

Spark ignitor will not light the
pilot after repeated pressing of
spark ignitor.

Pilot will not stay lit.

Burner will not light when
valve and burner switch are
both on.

Glass fogs up

Blue flames

Sooting

pOSSIBLE CAUSE

1. Battery needs replacing
2. Defective ignitor

3. Misaligned spark electrode

1. Defective thermocouple. Loose

thermocouple.

2. Air in gas line
3. No gas

1. Defective switch

2. Defective thermopile

3. Thermostat set too low/defec-

tive

1. Normal condition

1. Normal during start up

1. Flame impingement

REmEDy

1. Replace battery
2. Check connections to ignitor. Replace

ignitor if ignitor connections are good,
but there is no spark.

3. Check for spark arcing from the electrode

to pilot. Adjust by loosening screws on
pilot base. Adjust and retighten.

1. Check for proper connection of

thermocouple to rear of valve.

2. Bleed line. Contact dealer.
3. Check shutoff valve and gas supply

(LPG tank)

1. Check switch connections. Jump wires

at switch

2. Check connections to valve. Contact

dealer.

3. Turn up thermostat to start unit. check

thermostat connections.

1. Allow appliance to warm up. Glass will

clear. Additives in the gas may dirty
glass. Clean glass when cool.

1. Flames will yellow as appliance heats

up.

1. Check log position. Open shutters to

increase primary air.

Advertising
This manual is related to the following products: