58D6056

5

CSDV Series Direct Vent Gas Stove

pRODUCT FEATURES

pRODUCT SpECIFICATIONS

This appliance has been certified for use with either

natural or propane gas. See appropriate data plates.

This appliance is not for use with solid fuels.

The appliance is approved for bedroom or bedsitting

room installations.

The appliance must be installed in accordance with local

codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.

This appliance is mobile home approved.

The appliance must be properly connected to a venting

system.

The appliance is not approved for closet or recessed

installations.

For alcove installation see “Clearances,” Page 9.

ON

OF

F

FP2724
CSDV controls

Pilot

Optional
Remote
Receiver

Door

Figure 1 -
CSDV Cast Iron Stove Controls

Hi/Lo Knob

On/Off
Switch

Optional Blower

Ignitor Box
Located Under
Right Front Leg

FP2724

HIGH ELEVATIONS

Input ratings are shown in BTU per hour and are certi-
fied without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having
jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at eleva-
tions above 4,500 feet (1,370 m).

GAS pRESSURES

Natural

Propane (LP)

Inlet Minimum

4.5” w.c.

11.0” w.c.

Inlet Maximum

10.5” w.c.

13.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

max.Input min. Input

model

Fuel

BTU/h

BTU/h

Orifice Size

CSDV20NV Nat.

18.000

12,500

#43

CSDV20PV

LP

19,000

15,000

#54

CSDV30NV Nat.

28,000

17,000

#35

CSDV30PV

LP

28,000

21,000

#51

Front Rear

CSDV40NV Nat.

33,000

26,000

#46

#43

CSDV40PV

LP

33,000

30,000

#57 1.45 mm

GAS SpECIFICATIONS & ORIFICE SIZE