CSDV Series Direct Vent Gas Stove

AIR SHUTTER ADjUSTmENT (NATURAL GAS ONLy)

ADjUSTING THE AIR SHUTTER

The venturi of the burner is equipped with an air shutter. The opening of the venturi has been set
at 1/4" for Natural Gas and fully open for Propane installation at sea level. Natural Gas Models
may be adjusted for high altitude as follows:

To increase air mixture, pull down the adjustment rod located beneath the stove. This
opens the shutter more and will stop sooting. Figure 47

To decrease air mixture, push up the adjustment rod located beneath the stove. This
closes the shutter. Flames will be more yellow. Figure 48

ST1150
air shutter closed

Air Shutter

Adjustment
Rod

ST1149

Figure 47 -
Push Adjustment Rod Up to
Close Air Shutter

Lg1151
air shutter open

Air Shutter

Adjustment
Rod

ST1150

Figure 48 -
Pull Adjustment Rod Down
to Open Air Shutter