2. routine maintenance – Miller Electric Big 40 CX User Manual

Page 42

Advertising
background image

OM-4427 Page 38

9-2. Routine Maintenance

Y Stop engine before maintaining.

.

See Engine Manual and Maintenance Label
for important start-up, service, and storage

information. Service engine more often if

used in severe conditions.

Recycle engine

fluids.

n = Check

Z = Change

~ = Clean

l = Replace

* To be done by Factory Authorized Service Agent

Reference

Every

8

Hours

FUEL

WATER

Section 5-7,

9-7

n Fuel/Water Separator

n Fuel Level

n Oil Level

~ Oil, Fuel Spills

n Coolant Level

Every

50

Hours

Section 9-4

~ Air Cleaner Element

~ Weld Terminals

Every

100

Hours

~ Battery Terminals

n Air Cleaner Hoses

Every

250

Hours

1/2 in.

(13 mm)

Engine

Manual,

Section 9-5

l Unreadable Labels

n Fan Belt Tension

Z Oil Z Oil Filter

n~Spark Arrestor

Every

500

Hours

nl Weld Cables

Every

1000

Hours

OR

SLUDGE

FUEL Section 5-7,

9-7, 9-3 and

Engine

Manual

nRadiator Fluid Level

~ Inside Unit

Z FuelFilter

~ Drain Sludge

n~ Slip Rings*

nl Brushes*

nValve Clearance*

Every

2000

Hours

~ Injectors*

Advertising