OM-4427 Page 54

SECTION 11 − RUN-IN PROCEDURE

run_in1 11/05

11-1. Wetstacking

Y Do not perform run-in

procedure at less than 20

volts weld output and do not

exceed duty cycle or equip-

ment damage may occur.

1

Welding Generator

Run diesel engines near rated volt-

age and current during run-in period

to properly seat piston rings and

prevent wetstacking. See name-

plate, rating label, or specifications

section in this manual to find rated

voltage and current.

.

Do not idle engine longer than
necessary. Piston rings seat

faster if engine runs at weld/

power rpm, and the welding

generator is kept loaded during

run-in.

2

Engine Exhaust Pipe

Wetstacking is unburned fuel and

oil in the exhaust pipe and occurs

during run-in if the engine is run too

long at light load or idle rpm.
If exhaust pipe is coated with a wet,

black, tar-like substance, dry the

engine using one of the following

run-in procedures.
See the engine manual for addition-

al engine run-in information.