Master Lock E72 User Manual

Page 15

Advertising
background image

IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT. BEGIN AT STEP 1.

First Supervisor to Arrive

Function 31

Page 20

Valid User Code

Level: Grand Master

This function will override the set schedule, denying USERS access until a user with a MINIMUM ACCESS

OF SUPERVISOR (02-04) enters their code. After a supervisor enters their code, the schedule will resume
from that point.

To DISABLE the first supervisor function, enter "0".

To ENABLE the first supervisor function, enter "1".

ENTRIES

VISUAL / AUDIO

Note
The DEFAULT for this function is “0” DISABLED.
At 0000 HOURS this function RESETS.
ENTER “#”
to return to FUNCTION NUMBER (Step 2) and continue programming.

Select One:

(0) DISABLE

(1) ENABLE

0

*

1

*

Function Number

1

3

*

#

See Note

Exit

*

1.

2.

3.

4.

Function 32

Pin Only Entry

Page 21

IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT. BEGIN AT STEP 1.

Valid User Code

Level: Grand Master

Function allows a SHORTER LENGTH OF CODE to be entered by the user to gain access.
When ENABLED, user enters their PIN number FOLLOWED BY “*”.
The POSSIBLE PROBLEMS this function poses are:

SECURITY of the lock is COMPROMISED by fewer possible entries;

Possibility of DUPLICATE PIN NUMBERS;

AUDIT TRAIL is NOT RELIABLE with this function due to restricted retrieval information.

To ENABLE the PIN ONLY, enter "0".

To ENABLE the UID & PIN, enter "1".

ENTRIES

VISUAL / AUDIO

Note
The DEFAULT for this function is “1” (UID and PIN REQUIRED for entry).
User MUST enter PIN NUMBER and “*” to gain access.

ENTER “#” to return to FUNCTION NUMBER (Step 2) and continue programming.

Function Number

2

3

*

#

See Note

Exit

*

Select One:

(0) PIN ONLY

(1) UID & PIN

0

*

1

*

1.