Function 03

Add Group Schedule

Page vii

Day Code

Sample Function Programming Page

Valid User Code

Function 03

Group Schedule

Level: Master

Function schedules OPEN and CLOSE time/day for an established GROUP of
users. This function differs from the Basic Schedule (Func. 02), in that
specific GROUPS can be granted access.

(Military)

Hours

Minutes

Open Time

Close Time

Function Number

*

Mgmt. Defined

(Military)

Hours

Minutes

ENTRIES

VISUAL / AUDIO

Day Code

Must be entered as a 2 digit code.

01-07

Individual Days (Ex: Monday = 01)

08

Weekdays - Monday through Friday

09

Weekends - Saturday & Sunday

10

Even Weekdays - Tuesday & Thursday

11

Odd Weekdays - Monday, Wednesday & Friday

12

Override Pre-Programmed Holidays

13

All Days

Note
To DELETE ALL GROUP SCHEDULES, enter “0” in place of the DAY CODE then EXIT “*”.
For MANAGEMENT GROUPS (02-09) Group Schedule CANNOT be employed.
For USER GROUPS (10-99) Group Schedule CAN be employed.
ENTER “#” to RETURN to FUNCTION NUMBER and continue programming.

3

*

*

0

*

*

8

1

2

Group

#

See Note

Exit

*

07

00

17

00

0

Function Name

Function Description

LED /Audio Entry

Confirmation

G= Green

Y= Yellow

R= Red

Grey boxes are for

entering required

information

Function Number

Minimum Group

Security Level

Needed To

Program Function

1. Enter your

UID and PIN.

2. Enter

Function Number.

3. Enter Day

Code from list

below.

4. Enter

appropriate

Group Number.
5. Enter Open

Time.

6. Enter Close

Time.

Day Code

Note

Information

7. Enter * to exit

or to continue

programming,

enter # and return

to Function

Number. (Step 2)

White boxes are for

entering variable

information.

See Day Code

Mgmt. Defined

STEPS

IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT. BEGIN AT STEP 1.

Factory Code

9991234

Lock ID

User Defined 6 Digits

Level: Master

The LOCK ID INITIALIZATION process can be implemented ONLY using the FACTORY CODE.
This occurs when:

The lock is first installed

After the lock has been reset. (See page v.)

Initialize Lock ID

Page 1

IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT. BEGIN AT STEP 1.

#

ENTRIES

VISUAL / AUDIO

#

Note
The default LOCK IDENTIFICATION NUMBER for this function is 000001.
Use “0” to indicate blanks. (Ex. Room 321=321000 or 000321).
We recommend that each lock be given a unique ID Number.
In order to add the ID Number later, the lock must be fully reset.