Fail Secure

Function 36

Page 24

IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT. BEGIN AT STEP 1.

Valid User Code

Level: Grand Master

THIS FUNCTION IS ONLY INTENDED FOR USE IN BATTERY POWERED UNITS.
In case the low battery warning goes unnoticed, (See Battery Information page iv) and the lock runs out of
power, this function ensures that the E72 will fail in a secured state. At that time, a key will be required to
open the E72. If this function is not used, the lock will fail in the last state the lock was in.

EGRESS IS ALWAYS PERMITTED.

TO ENABLE Fail Secure, enter "0". This will set a POWER RESERVE to ENSURE the lock will fail CLOSED.

TO DISABLE Fail Secure, enter "1". This will allow the lock to fail in its last state - either open or closed.

Select One:

(0) FAIL SECURE

(ENABLED)

(1) DISABLE

Note
The DEFAULT for this function is “1” DISABLED.
ENTER “#” to return to FUNCTION NUMBER (Step 2) and continue programming.

0

*

1

*

ENTRIES

VISUAL / AUDIO

Function Number

6

3

*

#

See Note

Exit

*

1.

2.

3.

4.

IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT. BEGIN AT STEP 1.

Function 37

Set Alternative Terminator

Page 25

Valid User Code

Level: Grand Master

This function increases the SECURITY of the lock by REVERSING the TERMINATOR and PROGRAMMING

KEYS. This reversal adds another level of complexity to any attempt at hacking codes. (For more

information on the terminators, see page iii.)

To USE DEFAULT, enter "0". (“*” is the terminator and “#” is the programming key)

To ENABLE REVERSE, enter "1" (“#” is the terminator and “*” is the programming key).

Select One:

(0) DEFAULT “

*

(1) REVERSED “#”

Note
The DEFAULT for this function is “0” “*” as terminator.

ENTER “#” to return to FUNCTION NUMBER (Step 2) and continue programming.

0

*

1

*

ENTRIES

VISUAL / AUDIO

Function Number

7

3

*

#

See Note

Exit

*

1.

2.

3.

4.

Advertising