Table 13-47. odu rx parameters oids, 13 odu r – Mocomtech CIM-550 User Manual

Page 285

Advertising
background image

CiM-550 IP Enabled Satellite Modem

Rev. 2

SNMP interface

CD/CIM550.IOM

259

13.5.1.13 ODU R

X

P

ARAMETERS

Table 13-47. ODU Rx Parameters OIDs

OID Description

OduRxFequency

Receive frequency in KHz. Can be between 3,625,000 KHz
and 14,100,000 KHz.

oduRxAttenuation

Receive attenuation. Can be between 0..2500 in 0.01dB
where 0=0.00dB to 2500=25.00dB.

oduRxMute

Receive mute. Can be set to:

0 Disabled

1 Enabled

oduRxSlopeMode

Receive slope mode. Can be set to:

0 Manual

1 Calibrated

oduRxSlopeValue

Receive slope value. Can be between 0..10 in 0.1, where
0=0.0 to 10=1.0.

oduRxGainOffset

Receive gain offset. Can be between -400 and 0 in 0.01 dB,
where 0=0.00 dB to -400 = -4.00dB

Advertising