CiM-550 IP Enabled Satellite Modem

Rev. 2

Front Panel Menus

CD/CIM550.IOM

39

4.1.5.2.5 SELECT\CONFIG\REMCONT

DISPLAY SELECTIONS/DESCRIPTION

SELECT REMOTE CONTROL:

LOCAL REMOTE (PRESS ENT)

LOCAL

REMOTE

If LOCAL is selected then remote control will be
disabled. Remote monitoring is still possible.

If REMOTE is selected AND If the unit has not been
defined as an EDMAC SLAVE then the following
sub-menu will be displayed:

SELECT\CONFIG\REMCONT\REMOTE

DISPLAY SELECTIONS/DESCRIPTION

REMOTE CONTROL: BAUDRATE

INTERFACE (PRESS ENTER)

BAUDRATE

INTERFACE

EDIT LOCAL BUS BAUDRATE:

19200 BAUD FORMAT 8-N-1

BAUDRATE screen

Edit the baud rate of the remote control bus,
connected locally to the M&C computer.

Selections are 300, 1200, 2400, 4800, 9600
and 19200 baud are possible.

FORMAT selectionas are: 8-N-1, 7-E-2, 7-O-
2.

The asynchronous character format is FIXED
at 8 data bits, 1 stop bit, no parity (8-N-1).

SELECT. INTERFACE: EIA-232

EIA485-2W EIA485-4W (ENT)

INTERFACE screen

EIA232

EIA485-2W

EIA485-4W

At this point the user will be further prompted
to enter the bus address.

IN EIA-232 MODE THE BUS

ADDRESS IS FIXED AT 0000

In EIA-232 mode the bus address is
fixed at 0, and this screen is
displayed.

EDIT UNIT'S BUS ADDRESS:

0245 (PRESS ENTER)

If either RS485 mode is selected, this
screen is displayed.

The valid range of addresses is from
1 to 9999.