CiM-550 IP Enabled Satellite Modem

Rev. 2

Remote Control

CD/CIM550.IOM

73

Parameter
Type

Command
(Instruction

Code and
qualifier)

Arguments for

Command or

Response to
Query

Description of arguments
(note that all arguments are ASCII numeric

codes, that is, ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query
(Instruction

Code and
qualifier)

Response to

query
(target to
controller)

This command takes no arguments.

Force 1:1

Switch

FSW= None

Command

only.

Forces the unit to toggle the Unit Fail relay to the
‘fail’ state for approx 500ms. If the unit is a 1:1 pair,

and it is currently the ‘On Line’ unit, this will force a

switchover, so the unit will then be in ‘Standby’

mode. The command is always executed by the
unit, regardless of whether it is stand-alone, in a

1:1 pair, or part of a 1:N system.

This command takes no arguments.

FSW= (message ok)

N/A

N/A

10dB
attenuator
set

ATS=

1 byte, value of

0 or 1

FACTORY USE ONLY
Modulator output 10dB attenuator setting, where
0 = no attenuation
1 = 10 dB attenuation
Example: ATS=0
(Used for power-level calibration)

ATS= (message ok)
ATS? (received ok, but
invalid arguments found)
ATS* (message ok, but not

permitted in current mode)

ATS? ATS=n

where n is 0
or 1

Power level

DAC set

DAC= 4

bytes,

numerical

FACTORY USE ONLY
Modulator power output DAC setting. An argument
between 0000 and 4095 is required
Example: DAC=1287
(Used for power-level calibration)

DAC= (message ok)
DAC? (received ok, but
invalid arguments found)
DAC* (message ok, but not

permitted in current mode)

DAC? DAC=xxxx

where xxxx
is a value
between 0000
and 4095

Write
EEPROM
Value

EWR=

7 bytes

Command only. FACTORY USE ONLY
A command in the form ddd,aaa, where ddd is a

single byte data value between 0 and 255, and aaa
is a starting address (in the range 0 - 127) within

the serial EEPROM, where the data is to be

written.
Example: EWR=127,104 means write the value

EWR= (message ok)
EWR? (received ok,
but invalid arguments found)
EWR* (message ok, but not

permitted in current mode)

N/A N/A