background image

Figure 15. Write Data to Radio

When programming is complete, the RSS will revert to the "READ/PROGRAM" menu, the
radio will automatically reset, and the radio display will clear. If the display still shows an
"ERR X YZ" message after programming is complete, try reprogramming the radio. If the
error condition persists, contact your Motorola service representative, or see Appendix-1 for
a description of the error code.

Extraction:

The extraction feature enables you to easily change personalities in a radio without having to
realign the radio. During the extraction process, the RSS reads all the alignment data from
the radio to be programmed. This alignment data is then applied to the current radio
personality, which is then converted to codeplug(s) and written to the radio in the normal way.

In order to better understand the extraction process, an explanation of the normal alignment
process is necessary. First, assume that you have just created a new radio personality. The
RSS, not knowing what radio the personality is destined to occupy, inserts "default"
alignment values into the personality. These default values are necessary to ensure that a
radio will function when programmed with the personality. Next, assume that you must put
this personality into a radio that has never been aligned. You will write the personality to the
radio and, when prompted, select "F2 - Use Programmer Tuning Values." This is necessary
because the radio has never been aligned, and there are no existing alignment values to
extract from the radio.

40

Get/Save/Program Codeplug Data

F1

F4

F2

F3

F5

F6

F7

F8

F9

F10

MOTOROLA Radio Service Software
SABER Model:
Ver. R05.00.00

Main.Get/Save/Prog.Read/Prog.Program

WRITE DATA TO A RADIO

The RPF file conversion is complete.

0% 100%

................................................
................................................
................................................

Programming COPE Internal
Programming COPE External
Programming CORE 6d

Accessing Serial Bus.

R07.01.00

0%

100%

6D