Installation Instructions

Section 2

2-2

Location/Mounting

CAUTION

Do not install in an area where the air temperature
falls below 35

°F or exceeds 110°F.

The AuCS

®

A

must be protected if it will be

subjected to temperatures below freezing. Refer to
“Removal From Service/Winterization.”

HEIGHT REQUIREMENT
(Refer to drawing on page 2-3.) Either the base or the
top of the AuCS

®

A must be within 2” of the base of

the ice machine. Do not mount the AuCS

®

A too high

or too low.

CAUTION

The cleaner or sanitizer may siphon (or dispense
improperly)into the ice machine water trough if the
AuCS

®

A is mounted too high or too low.

DISTANCE REQUIREMENT
(Refer to drawing on page 2-3.) The AuCS

®

A must

be mounted within 9 feet of the ice machine to
accommodate the low voltage communication wire
and tubing. The tubing may be shortened to
accommodate a run of less than 9 feet.

CAUTION

Do not extend the length of the 9-foot low voltage
modular communication wire or tubing. The correct
amount of solution will not dispense.

FASTENING TO BIN OR DISPENSER

CAUTION

The AuCS

®

A accessory may be mounted to the bin

or dispenser only when permitted by local electrical
codes.

NOTE: The ice machine’s serviceability may be
reduced when the AuCS

®

A is mounted to the bin or

dispenser. Wall mounting is recommended.

1. Set the mounting bracket (part F, page 2-4) over

the bin top rail at desired location (refer to
figure).

2. Remove the backing from the foam adhesive tape

(part E, page 2-4). Apply tape to mounting
bracket, and along the entire bin rail.

3. Align the AuCS

®

A key slots with the mounting

bracket tabs. Verify the tabs are at the top of the
key slots and that the AuCS

®

A is level.

4. Remove the backing from the adhesive bumpers

(part D, page 2-4.) Attach bumpers to the
mounting bracket directly above the AuCS

®

A

control box. This eliminates upward movement
and stops the tabs from disengaging the key slots.

GASKET

BRACKET

Mounting to Ice Machine

FASTENING TO WALL
The AuCS

®

A is mounted to the wall using the two

key slots in the back wall of the accessory. Screw
fasteners (not supplied) must hold the entire weight
of the AuCS

®

A accessory (approximately 10 lb.).

Key Slot Dimensions

SV1640G

BUMPER

SV1634G

6.56”

16.6 CM

Advertising