Connection to ice machine (cont.), Communication wire connection, Determine type of solution needed – Manitowoc Ice AUCS Q User Manual

Page 20: Installing bottle of solution

Advertising
background image

Installation Instructions

Section 2

2-12

Determine Type Of Solution Needed

CAUTION

Use only Manitowoc-approved Ice Machine
Cleaner (part number 94-0546-3) or Sanitizer (part
94-0565-3) in the AuCS

®

A It is a violation of

Federal law to use these solutions in a manner
inconsistent with their labeling. Read and
understand all labels on the bottles before use.

The AuCS

®

A accessory will dispense Cleaner OR

Sanitizer. It cannot dispense both at the same time.

CAUTION

Do not mix Cleaner and Sanitizer solutions
together. It is a violation of Federal law to use these
products in a manner inconsistent with their
labeling.

MANITOWOC ICE MACHINE CLEANER
Part Number 94-0546-3
Ice Machine Cleaner is used to control build-up and
to remove lime scale or other mineral deposits. It will
not “sanitize” the ice machine.

It is recommended for use in places that have lime
scale or other mineral deposits built up, but no
problems with slime.

MANITOWOC ICE MACHINE SANITIZER
Part Number 94-0565-3

Ice Machine Sanitizer is used for sanitizing and
controlling algae build-up (slime) and other bacterial
growth. The ice machine should be sanitized on a
regular schedule, following Manitowoc
recommendations and local regulations.

It is recommended for use in places such as pizzerias,
bars, bakeries, etc., that have airborne bacteria
(yeast). Sanitizing is also recommended in places that
do not have lime scale (or other mineral deposit
problems).

Model

Amount of Cleaner or

Sanitizer Dispensed

Q200 Q280 Q320 Q370 Q420

Q450 Q600 Q600C IB600C

Q800 Q800C IB800C Q1000

Q1000C IB1000C SU1000C

Q1400C

*2.4 ounces (70 ml)

Q1300 Q1600 Q1800 QDUAL *4.8 ounces (140 ml)

*The dispense rate is automatically controlled

Installing Bottle Of Solution

WARNING

Wear rubber gloves and safety goggles (and/or face
shield) when handling Cleaner or Sanitizer.

CAUTION

Follow instructions listed under “Changing
Solution Type” on the next page when changing
from Cleaner to Sanitizer or from Sanitizer to
Cleaner.

1. Place the bottle into the AuCS

®

A accessory.

2. Slide the tube to the bottom of the bottle and

hand-tighten the cap.

TUBE MUST BE CLOSE

TO BOTTLE BOTTOM

SV1645

Bottle Installation

WARNING

Do not use 1 gallon bottles of Cleaner or Sanitizer
on the AuCS

®

A

Advertising