General, Electrical service, 115 volt wiring – Manitowoc Ice AUCS Q User Manual

Page 9: 220/240 volt wiring, Warning, Caution, Power cord, have an outlet installed

Advertising
background image

Section 2

Installation Instructions

2-1

Section 2

Installation Instructions

General

These instructions are provided to assist the qualified
installer. Check your local yellow pages for the name
of the nearest Manitowoc Ice Machine Distributor or
call Manitowoc Ice, Inc. for information regarding
installation and start-up services.

WARNING

Improper installation will affect dispensing rate.
Install only within the parameters outlined in this
installation manual.

Please contact your local Manitowoc Distributor or
call Manitowoc Ice, Inc. for assistance if you
encounter a problem that is not covered by this
manual.

Dimensions

Electrical Service

WARNING

All wiring must conform to local, state, and
national codes.

Voltage/Cycle/

Phase

Runnin

g Amps

N.E.M.A Electrical Plug

Configuration

115/60/1 .3

5-15P

220/240/50/1

.1

No plug attached

115 VOLT WIRING
The 115/60/1 AuCS

®

has an eight (8) foot cord

which must be plugged into a 15 amp electrical
outlet.

CAUTION

Never use an extension cord. If an outlet is not in
reach of the AuCS

®

power cord, have an outlet

installed.

220/240 VOLT WIRING
The 220/240/50/1 AuCS

®

can be wired to:

• The terminal block located in the ice machine.
• With a separate plug.
• To a separate disconnect.

220/240/50/1 Wiring

SV1632G

3.43 "

8.7 CM

12.12"

30.78 CM

9’

274.3 CM

8’

243 CM

12”

30.48 CM

TERMINAL BLOCK LOCATED

IN ICE MACHINE

L

1

L

1

P

R

E

-WIRE

D TO ICE

MACHINE

N N

GROUND

GROUND

TO SEPARATE FUSE/
CIRCUIT BREAKER.

DISCONNECT ALL POLES.

REFER TO ICE MACHINE
INSTALLATION
INSTRUCTIONS FOR
FUSE RATING.

AuCS

®

POWER

CORD

N

L

1

PRE-WIRED AT AuCS

®

ACCESSORY

SV1633G

Advertising