Installation Instructions

Section 2

2-4

Connection to Ice Machine

GENERAL

Parts Identification

PVC CONDUIT FITTING (A) INSTALLATION

½” PVC CONDUIT

FITTING

A

½” LOCKNUT (C)

½” PVC CONDUIT

FITTING (A)

B

HOSE CLAMPS

LOCKNUT

C

SV1636G

BUMPER

D

PVC Conduit Fitting (A) Installation

1. Insert the PVC fitting (A) into the AuCS

®

A and

tighten with the lock nut (C).

WARNING

Disconnect the electric power supply to the ice
machine at the electrical disconnect before
proceeding.

FOAM TAPE

E

2. If required for access, remove the front, top, and

right side panels from the ice machine.

BRACKET

F

3. Remove the 7/8” access hole plug located on the

back of the corner post of the ice machine

4. Insert the PVC conduit fitting (Part A) and

tighten with the lock nut (Part C).