Installation Instructions

Section 2

2-14

Setting Frequency Of Cleanings

The AuCS

®

A is factory-set to clean (or sanitize) the

ice machine approximately once every two weeks.
For less frequent cleaning, set the selector switch as
indicated below. (Refer to “Component Location and
Identification” for selector switch location.)

Switch

Position

Time Between

Cleanings

0

No cleaning (OFF)

1

Approximately 2 weeks

(1120 harvests)

2

Approximately 4 weeks

(2240 harvests)

3

Approximately 12 weeks

(6720 harvests)

NOTE: Switch positions 4-9 are inoperative. Do not
use them.

Important

Using the AuCS

®

A accessory is supplemental to

regular cleaning and sanitizing (per Manitowoc
recommendations and local regulations).

Removal From Service/Winterization

CAUTION

Leaving solutions in the AuCS

®

A in freezing

temperatures may result in severe damage to the
dispensing pump. A failure of this nature is not
covered by the warranty.

If the AuCS

®

A is to be removed from service for

extended periods, or if it is to be exposed to ambient
temperatures of 32

°F (0°C) or below, follow this

procedure:

1. Remove the Cleaning or Sanitizing solution

bottle.

2. Follow the instructions under “Hose Priming” to

pump all of the solution out of the dispensing
pump and line.