Section 2

2-10

Installation Instructions

Connection to Ice Machine (cont.)

COMMUNICATION WIRE CONNECTION
Insert the low voltage communication wire through
the ½” conduit connecting the AuCS

®

A to the ice

machine.

A to the ice

machine.

Plug into the jacks on the ice machine control board
and the AuCS

®

A control board. (Refer to drawing for

routing communication wire in ice machine.)

Plug into the jacks on the ice machine control board
and the AuCS















®

A control board. (Refer to drawing for

routing communication wire in ice machine.)

CONTROL BOARD

COMMUNICATION

WIRE

GROUND WIRE

(Q1300/Q1800 ONLY)

ROUTE WIRING

THROUGH

ACCESS HOLES

AS SHOWN

COMMUNICATION

WIRE

30 AND 48 INCH

22 INCH

SV1642G

Low Voltage Communication Wire Connection

QDUAL ONLY: The communication wire is attached to the rear of the ice
machine control box. The communication wire included with the

AuCS

®

A

is

not used.

AUCS CONTROL

BOARD

COMMUNICATION

PORT

QDUAL

COMMUNICATION

PORT