Specifications, 1 weld, power, and engine specifications, 2 dimensions, weights, and operating angles – Miller Electric Metro 250D User Manual

Page 19: 3 volt-ampere curve

Advertising
background image

15

OM-402

3. Specifications

3.1

Weld, Power, and Engine Specifications

Rated Welding

Output

Amperage

Range

Maximum

Open-Circuit

Voltage DC

Auxiliary Power

Rating

Engine

Fuel

Capacity

Average Sound

Level

280 A, 31 V DC,

60% Duty Cycle
250 A, 30 V DC,

100% Duty Cycle

20 − 280

61

(Average)

Single-Phase,

10 kVA/kW, 42 A,

120/240 V, 60 Hz

Deutz/Ruggerini

RD211 Air-Cooled,

Two-Cylinder, 23

HP Diesel Engine

11.8 US gal

(44.6 L)

74.5 dB(A) at

23 ft (7 m)

3.2

Dimensions, Weights, and Operating Angles

Dimensions

Height

41 in (1041 mm)

A

Y D d

i l

hil

Width

30 in (762 mm)

Y Do not exceed operating angles while run-

ning or engine damage will occur.

Y Do not move or operate unit where it could

tip

Depth

54-1/2 in (1384 mm)

tip.

A

29 in (737 mm)

B

25

°

B

36-3/4 in (933 mm)

25

°

25

°

15

°

C

9/16 in (14 mm) Dia.

15

°

Weight

C

4 Holes

angles 2/97 ST-158 938

960 lb (435 kg)

3.3

Volt-Ampere Curve

SA-180 261

The volt-ampere curve shows the

minimum and maximum voltage

and amperage output capabilities of

the welding generator. Curves of all

other settings fall between the

curves shown.

Advertising