Maintenance & troubleshooting, 1 routine maintenance, 50 h – Miller Electric Metro 250D User Manual

Page 28: 100 h, 200 h, 500 h, 1000 h

Advertising
background image

24

OM-402

7. Maintenance & Troubleshooting

7.1

Routine Maintenance

Recycle engine

fluids.

Y Stop engine before maintaining.

.

See also Engine Manual and Maintenance
Label. Service engine more often if used in

severe conditions.

8 h

Wipe up spills.

Check fluid levels.

See Section 4.3.

50 h

Clean and

tighten weld

connections.

Clean air filter element.

See Section 7.5.

100 h

Change oil.

See Section 7.3

and maintenance

label.

Clean and

tighten battery

connections.

See Section 4.2.

Clean cooling

system.

See engine manual.

200 h

Change oil filter.

See Section 7.3

and maintenance

label.

Change fuel

filter. See

Section 7.4.

Replace

unreadable

labels.

Change fuel

filter. See

Section 7.4.

250 h

300 h

Check valve

clearance.

See engine manual.

Check and clean

spark arrestor.

See Section 7.8.

500 h

Test/time injectors.

See engine manual.

Repair or replace

cracked cables.

1000 h

Blow out or

vacuum inside.

During heavy service,

clean monthly.

OR

Advertising