4 connecting to weld output terminals, 5 selecting weld cable sizes – Miller Electric Metro 250D User Manual

Page 23

Advertising
background image

19

OM-402

4.4

Connecting to Weld Output Terminals

Ref. ST-158 936-D / Ref. ST-175 918-C

1

Positive (+) Weld Output

Terminal

2

Negative (−) Weld Output

Terminal

For Direct Current Electrode Positi-

ve (DCEP), connect work cable to

Negative (−) terminal and electrode

cable (Stick) or torch cable (TIG) to

Positive (+) terminal.
For Direct Current Electrode Nega-

tive (DCEN), reverse cable con-

nections.
If unit has optional polarity switch,

connect work cable to Work

terminal and electrode or torch

cable to electrode terminal.

Tools Needed:

3/4 in

1

2

4.5

Selecting Weld Cable Sizes

Total Cable (Copper) Length in Weld Circuit Not Exceeding

Welding

Amperes

100 ft (30 m) or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

Amperes

10 − 60%

Duty Cycle

60 − 100% Duty

Cycle

10 − 100% Duty Cycle

100

4

4

4

3

2

1

1/0

1/0

150

3

3

2

1

1/0

2/0

3/0

3/0

200

3

2

1

1/0

2/0

3/0

4/0

4/0

250

2

1

1/0

2/0

3/0

4/0

2-2/0

2-2/0

300

1

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

350

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

400

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

2-4/0

Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.