Operating the welding generator, 1 front panel controls – Miller Electric Metro 250D User Manual

Page 25

Advertising
background image

21

OM-402

5. Operating the Welding Generator

5.1

Front Panel Controls

Ref. ST-175 918-C

9

Y Heavy loading during first 50 hours

will damage engine. Keep load less

than 225A (weld) or 7 kVA (power) for

first 50 hours.

1

Engine Control Switch

Use switch to operate glow plug (optional −

see table), start engine, select speed, and

stop engine.
In Run/Idle position, engine runs at idle

speed at no load, and weld/power speed

under load. In Run position, engine runs at

weld/power speed.

.

Use Run position for HF-start TIG

welding, and to maintain weld/power

speed under light auxiliary power loads.

2

Idle Lock Switch

Use switch to lock engine in idle speed dur-

ing start-up (see table).

Y Do not weld or use ac receptacles

with switch in Idle position.

To Start: move Idle Lock switch to Idle

position and Engine Control switch to Start

position. Release Engine Control switch

when engine starts. Do not crank engine if

engine is still turning. Move Idle Lock switch

to Run/Idle position after engine warms.
To Stop: turn Engine Control switch to Stop

position.
3

Engine Hour Meter

4

Fuel Gauge

5

Engine Oil Pressure Light

Engine stops and light goes on if oil pressure

is too low.
6

Polarity Switch (Optional)

Use switch to change polarity of weld output.

7

Arc Force (Dig) Control

Use control to automatically increase

amperage as arc length is decreased, to

assist in arc starts, and reduce the chance of

the electrode freezing in the puddle. Set at

minimum for TIG welding.
8

Amperage Control

9

Voltmeter (Optional)

10 Ammeter (Optional)
11 Amperage Control Switch
Use switch to select front panel or remote

amperage control.
12 Output (Contactor) Control Switch
Use switch to control remote contactor if

connected to remote 14 receptacle RC1.
Y Weld output terminals are energized

when Output (Contactor) Control

switch is On and engine is running.

0 s

10 s
20 s

70

°

F (21

°

C)

32

°

F (0

°

C)

−4

°

F (−20

°

C)

10

1

3

5

4

12

11

7

8

2

Using Glow

Plug

2150

rpm

3700

rpm

2150 rpm

(No Load)

3700 rpm

(Load)

2150

rpm

Using Idle Lock Switch

6