2 drive select (ds) jumper, 3 master jumper configuration, 4 jumper parking (pk) position – Maxtor D540X-4K User Manual

Page 24

Advertising
background image

Installation

3-6

Maxtor D540X-4K 20.4/40.0/60.0/80.0 GB AT

Once you install the CS jumper, the drive is configured as a Master or Slave by the
state of the Cable Select signal: pin 28 of the ATA bus connector. Please note that
pin 28 is a vendor-specific pin that Maxtor is using for a specific purpose. More than
one function is allocated to CS, according to the ATA CAM specification (see
reference to this specification in Chapter 1). If pin 28 is a 0 (grounded), the drive is
configured as a Master. If it is a 1 (high), the drive is configured as a Slave. In order
to configure two drives in a Master/Slave relationship using the CS jumper, you
need to use a cable that provides the proper signal level at pin 28 of the ATA bus
connector. This allows two drives to operate in a Master/Slave relationship
according to the drive cable placement.

The Maxtor D540X-4K 20.4/40.0/60.0/80.0 GB AT hard disk drives are shipped
from the factory as a Master (Device 0 - CS jumper installed). To configure a drive
as a Slave (Device 1- DS scheme), the CS jumper must be removed. In this
configuration, the spare jumper removed from the CS position may be stored on the
PK jumper pins.



&TKXG 5GNGEV &5 ,WORGT

You can also daisy-chain two drives on the ATA bus interface by using their Drive
Select (DS) jumpers. To use the DS feature, the CS jumper must not be installed.

To configure a drive as the Master (Device 0), a jumper must be installed on the DS
pins.

Note:

The order in which drives are connected in a daisy chain has no
significance.



/CUVGT ,WORGT EQPHKIWTCVKQP

In combination with the current DS or CS jumper settings, the Slave Present (SP)
jumper can be implemented if necessary as follows:

Note:

The CS position doubles as the Slave present on this drive.

• When the drive is configured as a Master

(

DS jumper installed or CS

jumper installed, and the Cable Select signal is set to (0), adding an
additional jumper (both jumpers DS and CS now installed) will indicate
to the drive that a Slave drive is present. This Master with Slave Present
jumper configuration should be installed on the Master drive only if the
Slave drive does not use the Drive Active/Slave Present (DASP–) signal
to indicate its presence.



,WORGT 2CTMKPI 2- 2QUKVKQP

The PK position is used as a holding place for the jumper for a slave drive in systems
that do not support Cable Select. The pins used for the parking position are vendor
unique.