ATA Bus Interface and ATA Commands

6-20

Maxtor D540X-4K 20.4/40.0/60.0/80.0 GB AT

NORMAL OUTPUTS - If the device has not detected a threshold exceeded
condition, the device sets the Cylinder Low register to 4Fh and the Cylinder High
register to C2h. If the device has detected a threshold exceeded condition, the device
sets the Cylinder Low register to F4h and the Cylinder High register to 2Ch.

ERROR OUTPUTS - If the device does not support this command, if SMART is
disabled or if the values in the Features, Cylinder Low or Cylinder High registers are
invalid, an Aborted command error is posted.

PREREQUISITES - DRDY set equal to one. SMART enabled.

DESCRIPTION - This co

mmand is used to communicate the reliability status of

the device to the host at the host’s request. Upon receipt of this command the device
sets BSY, saves any updated attribute values to non-volatile memory and compares the
updated attribute values to the attribute thresholds.

 5/#46 5#8' #664+$76' 8#.7'5

COMMAND CODE - B0h

TYPE - Optional - SMART Feature set. If the SMART feature set is implemented,
this command is optional and not recommended.

PROTOCOL - Non-data command

INPUTS - The Features register shall be set to D3h. The Cylinder Low register shall
be set to 4Fh. The Cylinder High register shall be set to C2h.

Cylinder High

C2h

Device/Head

1

1

D

Command

B0h

4GIKUVGT

















Error

na

UNC

na

IDNF

na

ABRT

na

na

Sector Count

na

Sector Number

na

Cylinder Low

na

Cylinder High

na

Device/Head

obs

na

obs

DEV

na

Status

BSY

DRD
Y

DF

na

DRQ

na

na

ERR