ATA Bus Interface and ATA Commands

Maxtor D540X-4K 20.4/40.0/60.0/80.0 GB AT

6-13

 5'6 %10(+)74#6+10

The SET CONFIGURATION command is secured to prevent accessing it
accidentally. To access the SET CONFIGURATION command, you must write the
pattern shown in Table 6-8 to the Command Block Registers. The first byte, FFh, is
a subcode to the extended command code F0h.

6CDNG  

Accessing the SET CONFIGURATION Command

0QVG Registers 1F2h

through 1F5h must contain the exact values

shown above. These values function as a key. The drive responds
by setting the ABRT bit in the Error register if the key is not
entered correctly.
To select the drive being reconfigured, register 1F6h should be
set. For execution of the command to begin, load register 1F7h

with F0h

.

 5'6 %10(+)74#6+10 9+6*176 5#8+0) 61 &+5-

The SET CONFIGURATION WITHOUT SAVING TO DISK command is
secured to prevent accidentally accessing it. To access this command, you must write
the pattern shown in Table 6-9 to the Command Block Registers. The first byte, FEh,
is a subcode to the extended command code F0h.

6CDNG  

Accessing the SET CONFIGURATION WITHOUT SAVING TO DISK Command

#&&4'55

8#.7'

&'(+0+6+10

1F2h

FFh

Set Configuration Subcode

1F3h

FFh

Password

1F4h

FFh

Password

1F5h

3Fh

Password

1F6h

AXh
(Drive 0)

Drive Select

BXh
(Drive 1)

Drive Select

1F7h

F0h

Extended Command Code

#&&4'55

8#.7'

&'(+0+6+10

1F2h

FEh

Set Configuration Subcode

1F3h

FFh

Password

1F4h

FFh

Password

1F5h

3Fh

Password

1F6h

AXh
(Drive 0)

Drive Select

BXh
Drive 1)

Drive Select

1F7h

F0h

Extended Command Code